A white background with a few lines on it

BURGESS COmpany

MCKEON DOOR

BURGESS COMPANY

A yellow and black mckeon logo on a white background

McKeon Door brings unique opening protective solutions for fire and storm shelter doors.

With more than 50 unique products, McKeon is a leading manufacturer of fire doors, fire shutters, fire curtains, smoke curtains, service doors and security grilles. With an emphasis on special purpose fire door systems, McKeon has provided architects and design professionals with numerous options and product performance not previously available, and that are only available from McKeon. Through thorough analysis and consultation, we’re able to develop a wide variety of applicable solutions for virtually any opening that needs protection. Gone are the days of closing down your open design to meet Fire & Life Safety code. 

CLICK ON PICTURES BELOW FOR FIRE & LIFE SAFETY PRODUCT DETAILS:

BURGESS COMPANY

FEMA RATED STORM SHELTER COILING STEEL DOOR

SafeSpace 500 Series

CC has adopted FEMA criteria for the design and construction of a safe room that provides near-absolute protection for occupants from wind and wind-borne debris. With SafeSpace 500, safe rooms and storm shelters can be constructed to FEMA 361 (3rd & 4th Editions) and  ICC 500 (2014 & 2020) Standards without sacrificing natural light and multi-purpose use. Utilizing McKeon’s wide span engineering capabilities, this technology will not restrict either the size or the number of openings that may be protected.


The latest edition of the IBC, Section 423, Storm Shelters, requires Group E occupancies and emergency facilities within the 250 MPH tornado and hurricane zones to incorporate safe rooms and storm shelters. These areas of refuge and safety can be detached structures or rooms within buildings. Regardless, all must comply with ICC 500 which incorporates, in large part, FEMA 361.


The SafeSpace 500 rolling steel door assembly is the only wide span opening protective to comply with strict ICC 500 and FEMA 361 wind-born debris requirements. Multi-purpose spaces may be designed with large unobstructed windows and light wells yet qualify as compliant safe rooms and storm shelters.

LEARN MORE

BURGESS COMPANY

FEMA HIGH WIND RATED COILING STEEL DOOR

Dynamic 110

An operational wind load of 110 mph combined with the durability of a McKEON wide span opening protective door assembly makes this product an ideal solution in any environment. Tested and certified for door assemblies up to 30 feet wide with a wind load introduced and maintained over the duration of a complete opening and closing cycle. Ensured operation during sustained wind loads offers the end user the flexibility to use these door assemblies in virtually any structure in any application. Guarantee consistent work schedules and protect building contents without compromising occupant safety.

LEARN MORE

BURGESS COMPANY

VERTICAL ACTING STEEL DOOR WITH FIXED EGRESS

SafeScape T5000 Series

This smoke and fire rated door assembly is designed to coil at the top allowing the rigid bottom frame with fixed egress doors to lower when deployed. Once in place, the single or multiple swinging egress doors provide complying egress. Large occupant loads and wide-span openings are easily accommodated by the McKeon T5000.


The Safescape® T5000 Series Fire Door Systems are generally used in high occupancy applications such as convention centers, casinos, arenas, sports centers and museums. Large occupant loads and wide-span openings are easily accommodated by the McKeon T5000.

LEARN MORE

BURGESS COMPANY

VERTICAL COILING STEEL WITH DEPLOYABLE EGRESS

SafeScape T2000 Series

A vertical coiling smoke and fire door system that incorporates either one or two deployable complying egress swing doors. Flush mounted in an adjacent wall, these complying egress swing doors deploy and lock into position at the command of an alarm condition. Once in place the integral egress doors and frames serve as side guides to accommodate a 3-hour roll-down door assembly that descends at a governed rate. Within seconds a 3-hour opening protective with single or dual egress swing doors stands ready to fight fire and smoke.


The Safescape ® T2000 Series Fire Door Systems with built in emergency egress are perfect for any retail, commercial, institutional, educational or health care application. They are ideal for use in occupancy separations, area separations, elevator lobby separations, horizontal exits, cross-corridor separations and corridor separations.

LEARN MORE

BURGESS COMPANY

VERTICAL COILING STEEL WITH NO EGRESS

AutoSet Model FSFD

The McKEON Auto-Set® Model FSFD is recommended in situations where fire and smoke protection is required but emergency egress is not an issue. The vertically acting fire door is UL, Intertek and Factory Mutual classified for up to four hours in both masonry and drywall applications. Also available with an acoustical rating, climate control insulation and smoke and draft rating.


The non-egress Model FSFD is recommended for use in schools, hospitals, convention centers, casinos, museums, airports, hotels and industrial facilities. They are frequently used in area separations, occupancy separations and corridor separations.

  • Custom built to any height and width
  • Self-closes without electricity or battery back-up
  • Requires very little head room and side room
  • Easy to test and automatically reset
  • Available in additional models:
  • FSFD-IS - designed for applications where fire protection is necessary and climate and temperature control are also critical
  • FSFD-STC - designed to protect openings that require both fire protection and sound control with up to a 34 STC
  • FSFD-TR is designed for use in areas where a Temperature Rise rating in addition to standard fire ratings is required
LEARN MORE

BURGESS COMPANY

VERTICAL COILING STEEL COUNTER SHUTTER

AutoSet CFS Series

The automatic resetting Auto-Set® Model CFS smoke and fire counter shutter can be designed to accommodate almost any opening variation up to 28 feet in width and 12 feet in height. Unlike conventional counter shutters the Auto-Set® Model CFS is easily tested and reset by on-site building personnel.


Auto-Set® Model CFS Smoke & Fire Counter Shutters are ideal for use in schools, hospitals, museums, casinos and other finished spaces. These units are designed and manufactured to accommodate both interior and exterior applications and are typically used in area separations and occupancy separations.

LEARN MORE

BURGESS COMPANY

SIDE SLIDING STEEL DOOR WITH OR WITHOUT EGRESS

SafeScape S7000 Series 

S7000 Series fire door systems are available in both manual or motor operated designs and with or without swing type egress doors. S7000 Series doors are side acting therefore ideal for openings in fire walls where headroom is limited. The side activated design enables these fire doors to navigate around tight curves and contoured openings.


The Safescape® S7400, S7500, S7700,and S7900 Fire Door Systems are ideal for any application where fire protection and emergency egress is needed and conventional swinging doors would not provide an adequate and desirable solution. The S7200 and S7600 are ideal for any application where only fire protection is required and egress is not an issue. Ideal applications are: cross-corridor situations in schools or hospitals and area separations. The S7000 Series Fire Door Systems have become increasingly designed into casinos, museums and retail areas.

LEARN MORE

BURGESS COMPANY

SIDE COILING STEEL DOOR WITH OR WITHOUT EGRESS

SafeScape S9000 Series

The Safescape® S9000 Series fire door system is a side coiling smoke and fire door with one or multiple integral swing type egress doors, a complying method of egress. The side coiling design makes this product ideal for openings in rated walls where headroom clearance is limited and enables the assembly to navigate around tight curves and contoured openings.


The S9000 Series Fire Door Systems are ideal for any application where emergency egress is required and conventional swinging doors would not provide an adequate design solution. Ideal applications are: cross-corridor situations in schools or hospitals. They have been widely designed into casinos, museums and retail spaces in area separations, occupancy separations and elevator lobby separations.

LEARN MORE

BURGESS COMPANY

SIDE ACTING ACCORDION STEEL WITH OR WITHOUT EGRESS OPTIONS

AC8000 Series

The AC8000 Series fire door systems are available in either manual or motor operated designs and can be provided with or without swinging egress doors. The units are made up of either 7-inch or 14-inch panels requiring a 9-inch or a 15 1/2-inch pocket profile, respectively.


The Safescape® AC8400, AC8500, AC8700, AC8800 and AC8900 fire door systems are ideal for any application where fire protection and emergency egress is needed and conventional swinging doors would not provide an adequate and desirable solution. The AC8200 and AC8600 can be used for any application where only fire protection is required and egress is not an issue.


Typical applications are: cross-corridor situations in schools and hospitals as well as area separations. They are ideal solutions for fire protection in area separation walls, occupancy separations, elevator lobby and corridor separations. The AC8000 Series fire door systems have become increasingly designed into casinos, museums and retail areas.

LEARN MORE

BURGESS COMPANY

HORIZONTAL ROLLING STEEL SHUTTERS

AutoSet H200 Series

The automatic closing H200 Series horizontal shutters prevent the migration of heat, smoke or hot/toxic gases by creating vertical compartments thereby separating the vertical spaces from one another. Horizontal fire shutters reduce construction costs. Smoke evacuation systems can become unnecessary and one horizontal fire shutter can be used in lieu of numerous conventional fire barriers on multiple floors.


The H200 is ideal for closing off penetrations in ceilings for atrium conditions as well as convenience stairways, escalator enclosures and skylights.


For detailed code analysis consult “Fire Door Systems, A Guide to Code Compliance.”

LEARN MORE

BURGESS COMPANY

VERTICAL FIRE FABRIC CURTAINS RATED 90 MINUTES - NO EGRESS

FireFighter Model D400

The D400 is a one-of-a-kind rolling curtain shutter that has been tested and labeled to UL 10B for 90 minutes with hose stream and UL 1784 smoke & draft. Unparalleled in the market, it is designed to protect openings in any wall rated up to 2 hours – including Fire Walls and Fire Barrier Walls!


A simple but unique configuration of textile layers permanently joined together as one unit and stored on a barrel in the head box. When deployed, the D400 rolls down as if it were a rolling steel door! A substantial opening protective ready to withstand heat, fire, smoke and the ultimate integrity test – the hose stream.

LEARN MORE

BURGESS COMPANY

VERTICAL FIRE RATED FABRIC CURTAINS WITHOUT EGRES

FireFighter Model D200E

The D200E offers a patented and burn-tested egress feature that complies with exiting requirements of the building codes. The FireFighter D200E Series is the only protective fire curtain assembly on the market with a 20-minute rating UL10B and UL10C without hose stream, up to 3-hour UL 10D rating, UL 1784 smoke and draft rating and integral conforming swing egress door(s). “The First Responder” is truly a first – going beyond where others leave off!


The D200E incorporates an egress feature that complies with the current model building codes as an opening protective placed in the required path of egress. Swinging doors as outlined in the egress sections of the model codes are the basis of design and acceptance for the FireFighter D200E fire curtain and its many applications where building occupant egress is required.

LEARN MORE

BURGESS COMPANY

VERTICAL FIRE RATED FABRIC CURTAINS WITH EGRESS

FireFighter Model D200

The D200 is an opening protective made of a flexible fire-rated fabric that is US laboratory tested and approved for unlimited widths. A first in the industry, the D200 carries a 20-minute rating UL10B and UL10C without hose stream, UL 10D for up to 3 hours, and UL 1784 for smoke and draft. FireFighter D200 is approved for use in multiple applications – whenever the 20-minute UL 10B or UL 10C rating is required for a fire door or shutter used to provide protection for an opening of any size in a rated wall.

LEARN MORE

BURGESS COMPANY

NON-RATED GRILLES AND SYSTEMS

There are multiple models available for non-rated options:



LEARN MORE

To schedule an architectural consultation or receive product or budgeting information, please contact Dusty Schuler at 918.402.3504 or dschuler@burgess-co.com

Share by: